Tender For corrigendum : supply of pu foam spray in 750ml packing. type- polyurethane foam sealant, meets- ca 25-4, density-1.25 ibs/ft3, service temperature-40f-200f. make: boss 333 (or) anabond darian adfoam 100 (or) of the same specification in loctite only.
Tender For supply of pu foam spray in 750ml packing. type- polyurethane foam sealant, meets- ca 25-4, density-1.25 ibs/ft3, service temperature-40f-200f. make: boss 333 (or) anabond darian adfoam 100 (or) of the same specification in loctite only.
Tender For a) miscellaneous repair works of station fob in mbq-kyn (main line)& diva-bsr section (22 fobs).b) painting of station fobs (08 nos.) with high bid performance coating system of zinc rich primer, epoxy intermediate coat and polyurethane top coat in tna-diva section. (tna station old fob (kyn end) at km 33/1-2,tna station north end fob at km 33/2-3, kalwa station fob (south end) at km 35/5-6, kalwa station new fob extension at km 35/6-7, kalwa station fob (north end) at km 35/9-10, mumbra station fob (csmt end) at km 39/13-14, mumbra station fob (kyn end) at km 40/1-2, diwa station fob (csmt end) at km 42/33@ 45"46@)c) estimate of painting of station fobs (06 nos.) with high bid performance coating system of zinc rich primer, epoxy intermediate coat and polyurethane top coat in diva-kyn section. (diva station middle fob at km 42/49-50, diva station kyn end fob at km 42/76-80, kopar stn.fob connected high level platform at km 46/15-47/01 at km dombivli stn., psc fobat km 48/2-3, dombivli stn. new fob ( end)at km 48/4-5, thk stn. new fob (csmt end) at km 49/14-15)
Tender For bid to ras corrigendum : supply of paint finishing (ral 7040) grey(n8010-007507) , paint polyurethane grey(n8010-007509) , black colour tin free spc a/f paint for boottop application(n8010p009604) , epoxy based primer for appication in ballast tank(n8010-p009678) , anti corrosive llps (grey/bronze) (n8010-p061944) , anti corrosive llps (alluminium) (n8010-p061977)
Tender For corrigendum : annual purchase of epoxy polyurethane based 11kv termination, 1.1kv straight jointing and 1.1kv cable live end sealing kits in various sizes
Tender For supply of miscellaneous items for anesthesia department (as per annexure-5) - 01 sga - i gelit should have non-inflatable, gel-like supraglottic airway device for maintaining an open airway, standard 15mm connector, an integrated bite block to prevent airway occlusion, a gastric channel for early regurgitation warning and suctioning, a buccal cavity stabilizer for easier insertion, and an epiglottis rest to prevent obstructionsize:- 1,1.5,2.0,2.5,3.0,4.0,5.0, intubating lma the lma should be sterile, phthalate free, 100 % silicone material, the lma should have a dynamic curve & atraumatic cuff that creates an effective oropharyngeal seal.the lma should have integrated manometer for continuous cuff pressure monitoring, recommend max. intracuff pressure of 60 cm h2o ,allow direct intubation with dual gastric drainage channel , an integrated bite block and must be mr safe , having intubating ability of et tube size ranging from 6.5 to 7.5 mm, dual gastric channel access to manage sudden gastridisection& 10 degree inclination .size:- 3,4,5, combined spinal & epidural set latex free disposable pencil point spinal needle 27g, 127.5 mm with grooved transparent hub with centering protective plastic sleeve, touhy needle with black eye - 18 g (1.3 x 88 mm). protrusion of spinal needle through the back eye of the epidural needle. with epidural catheter, filter, loss of resistance syringe and separate locking device -, epidural full set with catheter having 3 pairs of holes.latex free continuous epidural anesthesia kit containing g18/g16 epidural touhy needle with large crystal clear grooved transparent hub & epidural catheter of g20 /g 19 & length 100 cm. with catheter connector. epidural catheter in the kit is made of 2 layers - inner layer of polyamide & outer layer of polyurethane. epidural catheter has an atraumatic tip design - the catheter has a tapering tip up to 4 cm & 3 pairs of laser drilled holes for distribution of drug. the epidural catheter has graduation markings up to 25 cm & has smudge marking between 11 & 12 cm markings to indicate the position of the catheter tip in the epidural needle & also has a marking at the distal end for catheter connector. the kit also has a small compact ergonomic 0.2 micron epidural filter with pressure resistance of 7 bars. 10 ml loss of resistance syringe with leur slip and parabolic graduation markings., insulated echogenic needle with integrated extension tubing for nerve blocktransparent insulated (teflon coated) needles with depth markings for ultrasound compatibility of these lengths 25 mm (24g), 50mm (22g), 100mm (21g), 150mm (20g). the hub of the needle has an inbuilt cable for connecting to the stimulator & a tubing for injection of the drug by immobile needle technique, all sizes, 20 to 24 gauge with all size (25 to 150mm), pencil point needle (with introducer)pencil point spinal needle with introducer all sizes, agt tracheal tube cuff oral / pre formed south pole tube cuffed oral, 1 eye sizes: i.d. 3.5 9.0 mm semi-seated connector, cupped atraumatic tip, continuous x-ray marker, graduated, low-pressure cuff, blue pilot balloon, valve for luer and luer-lock syringes latex-free sterile ce and usfda approved, agt tracheal tube cuff nasal / pre formed south pole tube cuffed nasal only, 1 eye sizes: i.d. 3.5 8.0 mm semi-seated connector, cupped atraumatic tip, continuous x-ray marker, graduated, low-pressure cuff, blue pilot balloon, valve for luer and luer lock syringes latex-free sterile ce and usfda approved, inj. etomidate 10 ml, inj. sugammadex 2 ml, inj. sugammadex 5 ml, inj. rocuronium 5 ml, pct ( percutaneous tracheostomy tube) with forcefpercutaneous tracheostomy kit with guidewire, dilators, introducer needle, forceps, tracheostomy tube, syringe, scalpel, cannula, : eo (ethylene oxide) sterilizedsuitable for adult and pediatric patients (varies by size)medical-grade polymer and stainless steel (for metallic components)size:- 7.0 , 7